Heatwave 5.5 Heatwave 5.5 Product Image

Maximum Current Load: 23 amps max at 240 VAC

KW Operational Range: 2.2 to 5.5 KW

Voltage: 240 VAC (suitable for 208 VAC at reduced output)

Cycles: 50-60 HZ

Efficiency: 99%

Recommended Breaker Size 2005 N.E.C.: 30 Amp

Minimum Wire Size: #10 AWG Copper

Minimum activation flow rate: 0.5 GPM

Water Line/Outlet Size: 1/2” MNPT

Weight, Dry: 8 lbs.

Water Capacity: .4 Gallons

Height, Width, Depth: 11.0” x 7.0” x 2.5”

Housing: Plastic

Heating Chamber: Quartz

Elements: Six (6) thin film quartz elements

Safety Features: Hi-Limit Thermal Shutoff, Water & Electricity Linkage Switch, Residual Current Operated Protection

Heatwave 5.5 is not suitable for outdoor installations *check with local codes

Downloads

PDF DownloadDownload PDF