Paradigm

Paradigm™ Specifications

Maximum Current Load: 30 amps max at 240 VAC

KW Operational Range: 0.12 to 7.2 KW

Voltage: 240 VAC
(suitable for 208 VAC at reduced output)

Efficiency: 99%

Cycles: 50-60 HZ

Recommended Breaker Size 2005 N.E.C.: 30 Amp

Minimum Wire Size*: #10 AWG Copper

Nominal Heating Capability: 24,500 BTU’s Approximately

Minimum Operating BTU’s: 409 BTU’s

Minimum activation flow rate: 0.25 GPM

Water Line/Outlet Size: 3/8” Compression

Height, Width, Depth: 6.75” x 16.75” x 3.75”

Housing: Plastic

Heating Chamber: Stainless Steel

Elements: One (1) 7200 Watt Thick Film, Electrical Element

Included Accessories: None

Safety Features: Hi-Limit Thermal Cutout, Incoming/ Outgoing Temperature Sensors, Digital P.C.B.

Temperature Settings: 90 °F to 125 °F (32 °C to 52° C) in increments of 1°

Noise Level: less than 2 dB at Maximum Output

Standard Consumer Warranty: 10 years heating chamber and elements, 5 years parts

Flow rate at 77 °F temperature rise: 0.6 GPM

Gallons per hour at 77 °F temperature rise: 38 Gallons Per Hour

Flow rate at 40 °F temperature rise: 1.2 Gallons Per Minute

Gallons per hour at 40 °F temperature rise: 72 Gallons Per Hour

Notes: Fully Modulating Point of Use with incoming/outgoing temperature sensors

Paradigm is not suitable for outdoor installations *check with local codes
 

Downloads

PDF DownloadParadigm Specifications Sheet