Fortis 120

Specification

Estimation Guide
by Climate **

  Max Power Load
Power Requirements
Cycles
Power Rating
Energy Factor
2005 National Electric Code*
Minimum Wire Size*
Heating Capability
First Hour Rating
Temperature Set Point
Flow Capacity
Water Inlet Size
Water Outlet Size
Dimensions (WxHxD)
Weight
Installation
Clearance Requirements
Max Temp Rise ( ” T ) @ 3 GPM
120 amps max @ 240 VAC
208 - 240 VAC
50 - 60 Hz
28.8 kilowatts
0.98
125 amps, 2-pole common trip breaker
2 AWG, copper
98266 BTUs
230 gallons
85˚F - 140˚F (29˚C - 60˚C)
0.3 - 9.0 GPM
3/4” NPT
3/4” NPT
12.375 x 23.375 x 4.875” / 31.4 x 59.4 x12.4 cm
65 lbs / 29.5 kg (est.)
wall mounted on supplied brackets
top: 30” sides: 6” bottom: 16” front: 24” back: 0”
86˚F
Summer

Showerhead Showerhead Showerhead +

 

Winter

Showerhead Showerhead +

 

Fortis 80

Specification

Estimation Guide
by Climate **

  Max Power Load
Power Requirements
Cycles
Power Rating
Energy Factor
2005 National Electric Code*
Minimum Wire Size*
Heating Capability
First Hour Rating
Temperature Set Point
Flow Capacity
Water Inlet Size
Water Outlet Size
Dimensions (WxHxD)
Weight
Installation
Clearance Requirements
Max Temp Rise ( ” T ) @ 3 GPM
80 amps max @ 240 VAC
208 - 240 VAC
50 - 60 Hz
19.2 kilowatts
0.98
80 amps, 2-pole common trip breaker
4 AWG, copper
98266 BTUs
153 gallons
85˚F - 140˚F (29˚C - 60˚C)
0.3 - 9.0 GPM
3/4” NPT
3/4” NPT
12.375 x 23.375 x 4.875” / 31.4 x 59.4 x12.4 cm
65 lbs / 29.5 kg (est.)
wall mounted on supplied brackets
top: 30” sides: 6” bottom: 16” front: 24” back: 0”
57˚F
Summer 

Showerhead Showerhead+

 

Winter

Showerhead Showerhead +

 

 

* Check with state and local codes.
**Based on 2 GPM at 55˚F rise (winter) and 2 GPM at 40˚F rise (summer). For illustrative purposes only.